2. Elaboration Question 1
Course subject(s)
2. Primary treatment
QUESTION 1 Headloss
Determine the headloss (hL) across the bar screen if:
- The screen is clean.
- If 50% of the screen is blocked.
Parameter | Symbol | Units | Value |
Incoming flow velocity | v | m/s | 0.6 |
Pass-through velocity (for clean screen) | V | m/s | 0.9 |
Screen cross sectional area | Aopen | mĀ² | 0.19 |
Friction coefficient for clean screen | C | – | 0.7 |
Friction coefficient for clogged screen | C | – | 0.6 |
Elaboration Question 1
Urban Sewage Treatment by TU Delft OpenCourseWare is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Based on a work at https://ocw.tudelft.nl/courses/urban-sewage-treatment/.